Turbomite - Acetal-Body (Plastic) Turbine Vibrator - Back to Turbine Vibrators
+ Ideal for clean rooms, nothing else like it
+ Etched label, no chance of contamination
+ All exposed parts are 304 stainless steel
+ Requires no lubrication
+ More force at lower air consumption than competitors' models
+ State-of-the-art CNC Machining
+ Improved Technology
+ Very quiet below OSHA Standards
+ Longer life than ball vibrators
+ Acetal Body is FDA and USDA compliant for food applications
|
| Model |
A in/cm |
B in/cm |
C in/cm |
D in/cm |
E in/cm |
F in/cm |
G in/cm |
H in/cm |
Wt. lbs/kg |
Un-Balance in-lbs/cm-kg |
| CVT-P-10* |
1-1/2" 3.8 |
1-9/32" 3.3 |
31/32" 2.5 |
3/16" .48 |
7/32" .56 |
#10-32 |
#10-32 |
10-32 UNF |
0.1/.05 |
0.002/.003 |
| CVT-P-30 |
2-3/4" 7 |
1-3/4" 4.4 |
1-1/4" 3.2 |
3/8" .95 |
11/32" .87 |
1/8" NPT |
1/8" NPT |
NA |
.54/.25 |
.013/.017 |
| CVT-P-50 |
4" 10.2 |
2-1/2" 6.4 |
1-5/8" 4.1 |
3/4" 1.9 |
3/8" .95 |
1/4" NPT |
1/4" NPT |
NA |
1.4/.62 |
.044/.052 |
| CVT-P-60 |
4-1/8" 10.5 |
2-11/16" 6.8 |
2-1/16" 5.2 |
11/16" 1.7 |
7/16" 1.1 |
1/4" NPT |
1/4" NPT |
NA |
1.24/.57 |
.12/.14 |
Note: The CVT-P-10 has two 10-32 UNF threaded holes in the end near the through hole. The other units do not have this feature.
| Model |
@ 20 psi/1.4 bar |
@ 40 psi/2.8 bar |
@ 60 psi/4.1 bar |
@ 80 psi/5.5 bar |
Speed vpm |
Force lbf/N |
Air Cnsmp cfm/lpm |
Speed vpm |
Force lbf/N |
Air Cnsmp cfm/lpm |
Speed vpm |
Force lbf/N |
Air Cnsmp cfm/lpm |
Speed vpm |
Force lbf/N |
Air Cnsmp cfm/lpm |
| CVT-P-10 |
18200 |
18.8 83.5 |
.49 13.8 |
19400 |
21.4 95.0 |
.78 13.8 |
20500 |
23.9 106.1 |
1.09 30.8 |
20900 |
24.8 110.1 |
1.41 39.9 |
| CVT-P-30 |
8400 |
26 115.4 |
.96 27.2 |
9840 |
35.8 158.9 |
1.6 44.5 |
10580 |
41.3 183.4 |
2.2 61.2 |
11300 |
47.1 209.1 |
2.8 78.4 |
| CVT-P-50 |
5670 |
45.1 200.2 |
1.7 48.6 |
7220 |
65.1 289.0 |
2.8 80.2 |
7810 |
76.2 338.3 |
3.8 109.5 |
8070 |
81.4 361.4 |
4.9 138.4 |
| CVT-P-60 |
4800 |
78.5 348.5 |
1.3 35.9 |
5910 |
119.1 528.0 |
2.0 58.0 |
6280 |
134.5 597.2 |
2.8 79.6 |
6560 |
146.8 651.8 |
3.6 101.2 |
Note: Date for this table obtained on 1000 pound laboratory test block. Frequency of vibration and resulting force output will decrease on a less rigid structure or mount.
Download Page in PDF Format
|
|
|
|
|
|
Cleveland Vibrator Company 2828 Clinton Avenue Cleveland, Ohio 44113 Phone: 216-241-7157 phone: 1-(800) 221-3298 Fax: 216-241-3480 Email: sales@clevelandvibrator.com |
We accept Visa, Mastercard, and American Express
 |
|
|
|
|